Requirement |
IHRA - National |
NHRA |
Top Speed Motorplex Inc. |
|
Facility Size (Dependent on Layout) |
200 - 300 Usable Acres |
Min 100 Acres |
138 Acres + |
|
Width (Recommended) |
60' |
60' (58' + 1' Walls) |
60' (58' + 1' Walls) |
|
Width (Minimum) |
60' |
60' |
60' (58' + 1' Walls) |
|
Length (Minimum) Start-Finish |
4000' |
4000' |
4904' |
|
Length (Recommended) Start-Finish |
4500' |
3960' |
4904' |
|
Run Off (Recommended) |
200' |
Not Specified |
278' |
|
Run Off (Surface) |
Sand |
Not Specified |
Gravel |
|
Turn Off Gates (1st Used For Emergencies) |
Not Specified |
300 Beyond 1/4 mile |
301 |
|
Turn Off Gates (For Racers) |
Not Specified |
1320 Beyond 1/4 mile |
1321 |
|
Turn Off Gates (Amount) |
Not Specified |
3 |
3 + 1 At The End |
|
Concrete Launch Pads (At Starting Line - Min) |
300' |
330' |
1320' |
|
Concrete Launch Pads (At Starting Line - Rec) |
750' |
660' (1/8 mile) |
1320' |
|
Burnout Box (Location) |
Not Specified |
90' Behind Starting Line |
105' Behind Starting Line |
|
Burnout Box (Size) |
Not Specified |
Not Specified |
10'x6' |
|
Christmas Tree (Location) |
Not Specified |
42' In Front Of Starting Line - 20' ?? |
41'8" |
|
Retaining Walls Start-Finish (Width) |
Not Specified |
1' |
1' |
|
Retaining Walls Start-Finish (Height) |
28" - 1000 ft / 38" To the End |
Not Specified |
28" - 1000 ft / 38" To the End |
|
Retaining Walls Start-Finish |
Concrete Wall - Double Stack Guardrail |
Highway Type |
Concrete Wall |
|
Retaining Walls Start-Finish |
Adjacent To Track - No Openings |
Not Specified |
Adjacent To Track - No Openings |
|
Guardrail Posts (Max Distance) |
12'6" |
Not Specified |
12' |
|
Guardrail Posts (Center) |
6'3" |
Not Specified |
6' |
|
Guardrail Posts (Max Gap - Under) |
2" |
Not Specified |
1" |
|
Staging Lanes (Minimum - Amount) |
8 Lanes |
6 - 10 Lanes |
7 Lanes |
|
Staging Lanes (Minimum - Length) |
300' |
200' |
500' |
|
Staging Lanes (Minimum - Width) |
Not Specified |
10' |
9'6" Width + 6" Painted Lines |
|
Crowd Control Fence (Location) |
Pits - Track - Return Road |
Pits - Track - Return Road |
Pits - Track - Return Road |
|
Crowd Control Fence (Location) |
Not Specified |
60' - 80' From Track Minimum |
|
|
Crowd Control Fence (Location - Burnout - 1/8) |
25' |
Not Specified |
25'2" |
|
Crowd Control Fence (Location - 1/8 - Shutdown From Retaining Walls) |
50' |
Not Specified |
50' |
|
Crowd Control Fence (Minimum - Height) |
4' |
Not Specified |
4' |
|
Perimeter Pit Fencing (Fans & Racers) |
Recommended |
Not Specified |
Installed |
|
Racing Surface (Desired) |
+ / - 1/10" |
Less Then 1% Grade Change |
+ / - 1/10" |
|
Grand Stands (Minimum - Spectators) |
10,000 (State Approved) |
Not Specified |
30,396 State & Federal Approved |
|
Grand Stands (Recommended Angle) |
Not Specified |
10 Degrees |
10 Degrees |
|
Grand Stands (Recommended Height) |
Elevated Above Guardrails |
Elevated Above Guardrails |
4' |
|
Pit Area (Racing Rigs) |
800 |
600 |
791 |
|
Pit Area (Bathroom) |
Not Specified |
2 (One having Showers) |
7 (One has Showers) |
|
Pit Area (Minimum Racing Rigs - Paved Parking) |
200 out of 800 (5 Acres) |
Not Specified |
Fully Paved |
|
Pit Roads (Width) |
30' |
Not Specified |
40' |
|
Concession Stands / Restrooms |
Meet Health Departments Specs |
Main One Behind Grandstands |
Meet Health - Inside Grand Stands |
|
Timing Tower / Control Tower |
Meet the needs of Operations |
2-3 Floors (Min) |
Meets Operations Needs - 3 Levels |
|
Timing Tower - (Angle to The Track) |
Not Specified |
70 Degrees (Jet Cars) |
0 Degrees- Raised Platform |
|
Timing Tower - Press Room |
Suggested |
Not Specified |
In Tower |
|
Timing Tower - Elevation |
Not Specified |
Minimum 15' |
60' |
|
Timing Tower - Working Area |
Not Specified |
Minimum 12' x 10' |
60' x 18'5" |
|
Timing System |
Compulink |
Not Specified |
Compulink |
|
Fire Equipment (Minimum In Pounds) |
50 lbs |
Not Specified |
250lbs |
|
Fire Crew |
Personal Trained Must Be Present |
Not Specified |
1 In House & Leesburg Fire Dept |
|
Ambulance (Minimum - Amount) |
1 |
Not Specified |
1 In House & Leesburg EMT's |
|
Lighting |
Track, Parking, Pits, Staging Lanes |
Not Specified |
Track, Parking, Pits, Staging Lanes |
|
Lighting (First 1320) Distance Between |
Not Specified |
150' |
150' |
|
Lighting (Shutdown) Distance Between |
Not Specified |
200' |
200' |
|
Lighting (Type) |
Not Specified |
3x - 1000 Watt - 480 Volt - Metal Halide |
3x - 1000 Watt - 480 Volt - Metal Halide |
|
Lighting Height of Poles |
Not Specified |
60' |
70' |
|
TV Production Truck Hospitality (Minimum) |
1 - 220 Volt, 220 Amp Power |
Not Specified |
4 - 220 Volt, 220 Amp Power |
|
Telephone Hook ups (Minimum) |
25 |
Not Specified |
75 |
|
Telephone Hook ups (Requirements) |
50 |
Not Specified |
75 |
|
ET Booth (Location) |
Return Road - Adjacent To Shutdown |
Not Specified |
Return Road - Adjacent To Shutdown |
|
Scales |
Return Road - Adjacent To Shutdown |
Not Specified |
Return Road - Adjacent To Shutdown |
|
Impound Area (Inspect Vehicles) |
Required |
Not Specified |
Return Road - Adjacent To Shutdown |
|
Premium Parking for Guests and Sponsors |
Required |
Not Specified |
Adjacent To Handicap Parking |
|
Manufacturers Midway (Display Products) |
Required |
Not Specified |
Yes |
|
Fuel Center |
Recommended |
Recommended (Nearby Staging Lanes) |
Return Road - Nearby Staging Lanes |
|
Compressed Air |
Not Specified |
Recommended (Away From Fuel Center) |
3 Locations on East Side of Paddock |
|
Scoreboards (Elapse Time & MPH of Each Lane) |
Required |
Daktroniks LED |
Daktronics DR-4883-36-11 |
|
Public Address System |
Required |
Not Specified |
Installed |
|
Race Track Surface 1st Layer (Lowest) |
Not Specified |
14" Lime |
14" Lime |
|
Race Track Surface 2nd Layer |
Not Specified |
10" Soil Cement |
10" Soil Cement |
|
Race Track Surface 3rd Layer (First 1/8) |
???" Concrete |
9" Concrete 5000psi Minimum |
9" Concrete 7500psi Minimum |
|
Race Track Surface 3rd Layer (1/8 to Shutdown) |
Not Specified |
3" Polymer Asphalt Mix |
3" Polymer Asphalt Mix |
|
Track Direction |
Not Specified |
West - East |
West - East |
|
Return Road (Width - Minimum) |
Not Specified |
24" Wide + 12' For Time Slip = 36' |
24 Wide + 12'6" Express Lane |
|
Return Road (Width - Minimum) |
Not Specified |
20' Minimum |
24 Wide |
|
Return Road (Distance From Barrier - Minimum) |
Not Specified |
100' |
167'10" |
|
Return Road (Protection) |
Not Specified |
Not Specified |
Concrete Retaining Wall - With Fence |
|
Parking Area (Patrons - Minimum) |
Not Specified |
2000 Spaces |
A: 3031 B: 5733 C: 20000+ |
|
Pull Boxes |
Not Specified |
25' - 30' |
|